* Advertisement *
20260420 WC 900x130

Wollongong CLT School Tests Four Times Tighter Than Passivhaus

The national association now counts 201 certified Passivhaus projects in Australia, whilst the federal government’s own Your Home guide still tells readers there are 25.


Wed 04 November 26

SHARE

A cross-laminated timber school in Wollongong has tested four times tighter than the Passivhaus standard demands, with The Illawarra Grammar School’s Hoskins Building among a fast-growing number of Australian buildings designed to it. That is according to betti und knut architecture, whose school building took the Grand Prix at the 27th Australian Timber Design Awards last month, ahead of Sydney Fish Market and the Adelaide Aquatic Centre.

“Hopefully it will have implications for other schools as well,” said Knut Menden, who runs the practice with Bettina Steffens, after the building opened earlier this year. His practice says it is the first commercial project in Australia to specify cross-laminated timber beams and columns, joined by Hilti quick connectors that let the whole frame be taken apart.

Spruce does the structural work, with the practice counting 850 cubic metres of PEFC and FSC-certified cross-laminated timber across the walls, floors, roof, stairs, ceilings, and joinery. It says that inherently airtight structure was fundamental to the school’s airtightness result, and a cross-laminated timber slab holds up its 1,000-square-metre green roof.

Desks in a classroom lined with exposed spruce cross-laminated timber walls, with timber-framed windows looking out over trees to a mountain
A classroom inside the Hoskins Building, where the spruce cross-laminated timber walls are left exposed and the windows look out to the Illawarra escarpment. (Photo Credit: Martin Mischkulnig)

Triple glazing, minimal thermal bridging, and heat-recovery ventilation cut the school’s heating and cooling demand by an estimated 80 per cent, according to the practice. It estimates the timber stores 630 tonnes of carbon dioxide, and says leaving that timber exposed did away with many secondary finishes.

“It provides an environment for students with exceptional comfort, natural light and air quality,” said Dr Julie Greenhalgh, the school’s principal, before the building opened in May. The school says filtered fresh air reaches every classroom through heat-recovery ventilation.

Kevin Peachey, head of built environment programs at WoodSolutions, the awards’ major partner, measures progress by how widely that excellence translates into “everyday building practice”. WoodSolutions has already published a case study on Coburg’s Hütt 01, a cross-laminated timber family home certified to Passivhaus Premium.

Four people stand in front of the Australian Timber Design Awards banner holding the burl timber Grand Prix awarded to betti und knut architecture for the Hoskins Building
Kevin Peachey, head of built environment programs at FWPA and WoodSolutions, on stage with betti und knut architecture and the Grand Prix for the Hoskins Building. (Photo Credit: Leo Mamede / Australian Timber Design Awards)

Meanwhile, Passivhaus certifications have more than quadrupled across Australia, with the Australian Passivhaus Association counting 201 certified projects in October, up from 48 at the end of 2022. The association told Melbourne practice Zen Architects on Tuesday that its count includes private homes never listed publicly.

“For too long the conversation about Australian housing has been about how many homes we build, not how well they perform,” said Stalin Chakrabarty, the association’s chief executive. He said a finished Passivhaus on a hot afternoon shows how comfortable a building can be without air conditioning, ahead of open days that put 48 projects on show later this month.

Yet the federal government still tells readers of its Your Home guide that Australia has 25 certified Passive Houses. By contrast, Zen Architects counts 149 in the German Passive House Institute’s public database, where listed certifications climbed from six in 2019 to 33 last year.

Rows of green tiered seats in an auditorium lined with exposed spruce cross-laminated timber walls, with stage lights hanging from a ceiling rail
The auditorium in the Hoskins Building, where exposed cross-laminated timber lines the walls behind tiered seating. (Photo Credit: Martin Mischkulnig)

“Growth from a small base is still small,” wrote Luke Rhodes of Zen Architects, in an analysis updated on Tuesday. He found those 33 buildings held 38 homes, fewer than one in every 4,500 Australia completed that year.

Certified homes are passing the airtightness test with room to spare, with Rhodes finding a median result of 0.46 air changes an hour across the 63 association register listings that publish one. The Hoskins Building’s 0.15 would sit among the four best on that register, whilst the federal government says the average new Australian home tests at 15.4.

As it stands, the Hoskins Building is still awaiting final certification to the international standard, according to the architects’ awards entry. Its judges have already called it “a proud beacon for what we should be building in Australia”.

Author

  • J Ross headshot

    Jason Ross, publisher, is a 15-year professional in building and construction, connecting with more than 400 specifiers. A Gottstein Fellowship recipient, he is passionate about growing the market for wood-based information. Jason is Wood Central's in-house emcee and is available for corporate host and MC services.